Saf t vent ci plusci 316 is appropriate for use on category i, ii, iii and iv gas firedappliances with maximum fluegas temperatures of 550f. Air admittance valve studor vent definition, installation, uses. When the flow stops, the mini vent closes by gravity, preventing any transmission of foul air. Buy ezflo 86075 studor minivent air admittance valve. Studor air admittance valve recess box with faceplate. The mini vent is set to hi gain input from the factory to get the most out of the drive section when used with low to medium output instruments.
Videos, extensive knowledgebase, technical specifications. Active drainage ventilation maxifiltra dn code 75110 8fstu019blk studor maxifiltra code 8fstu022ylw studor maxifiltra cartridge code. The toilet specifications will determine the exact studor model needed. Studer micro series operating instructions manual pdf download. The mini vent is used as an alternative to extending. Une distance dedition entre deux sequences est proportionnelle au nombre mini. Ab switches between two programmable settings of the mini vent ii. Take out the vent and drape something light over it like saran wrap.
Type l vent is designed for appliances requiring negative or neutral pressure venting systems. Vent as much as 160 dfu with the studor mini vent, the type most commonly used in the household. Studor mini vent 49009, 49010, 49018 air admittance inductone way dn 40 air admittance valve r112 94 fixture units group 7. A common problem in plumbing remodeling is figuring out how to run new vent lines when access to the existing drainwaste vent system is blocked by some structural element. To activate the termination on the xtender, move the two miniswitches to position t, and to. This manual contains information relating to the functioning of the rcc02. Convertissez des fichiers word, powerpoint et excel depuis et en pdf. The consent of studer can be obtained but is not limited to the case in which the interface software can not be provided by studer. If your organs output is too low to get enough drive, the mini vent can be switched to hi gain. Studor 20341 mini vent with pvc adapter 1 2 inch or. Product informationspecification sheet studor minivent. Saft vent ci plusci 316 is a double wall special gas vent that is ul tested and listed to the ul 1738 standard. Studor minivent air admittance valve with pvc adapter at. Sewer gas smell coming from studor vent installed under kitchen sink about a year ago hi we had a problem with drainage in our kitchen sink after a remodel.
Page 16 reverse engineering is only permitted with the express consent of studer. Just to be sure, i purchased an oatey sure vent and replaced he studor. The studor minivent or redi vent may serve as the termination point for. While ryans photo of the studor minivent label shows a blank at the maximum dfus column for the 1 12 diameter drain line, the companys technical product manual pdf given above in this article shows that on a 1 12 diameter horizontal drain, the minivent can handle a maximum of 3 dfus.
Air admittance valve seems to be a problem terry love. Due to space limitations, he installed it sideways and didnt glue the pvc pipes together so its easily removed. This type is also equipped with an antirodent feature that can reduce extermination costs over the life of the product, according to studor s website. Delivre au format pdf, ces donnees obtiennent une seule. In all cases, ensure that there is sufficient ventilation around the batteries.
Since the dsp core holds all audio in floatingpoint format, basically no clip. Air admittance valve studor vent definition, installation. I have a toilet that wont flush properly unless the studor. Dimensional data and weights service clearances and access panel locations a b k l h j n m p q c e g e g f f d d back view front view exhaust discharge exhaust intake. Make sure you have a sd card with the file for the language you wish to use. Convertissez des presentations powerpoint en documents pdf. I recently moved into a newer 1997 house which has at least six or seven airadmittance valves. It may seem like all hope is lost, but dont let that small roadblock get in the way of your dream kitchen makeover. Saft vent ci plus and ci 316 components are compatible and may be combined for installa. Sustainable land management practiced on smallscale farms in machakos, kenya. The mini vent is a solution for any single fixture and for a group of fixtures connected to a single branch, i. Get plumbing ventilation to prevent the loss of water seals in traps without the need for costly roof penetration using this studor pvc mini vent adapter.
If you just need a mono signal the r mono output delivers the best quality, particularly in stop mode. All air vents and openings for operating elements faders, rotary knobs must. The mounting diagrams in this manual are for illustration purposes only. Dec 08, 2016 this video is a response to a video i made previously suggesting that you should cap any open the vent pipes, but that was before i knew about air admittance valves. In any case studer has to be informed immediately upon complete or partial reverse engineering. Optional mounting by use of the watertite stabilizer bar allows the box to be positioned anywhere in the stud bay. Install a pvc reducer in the tees port with pvc glue. The unique design of the studor mini vent provides plumbing ventilation to prevent the loss of water seals in traps without the need for costly roof penetration and vent piping. In this jack accepts mono guitar, organ and keyboard signals. All air vents and openings for operating elements faders, rotary knobs must be checked on. To read pdf files, you need the adobe acrobat reader 6. Can be used as an individual, branch, circuit or stack vent fits 1 12 and 2 pipe sizes will vent up to 160 dfus on a branch will vent up to 24 dfus on stack. Studor redivent with pvc adapter valve20353 the home depot.
There is no one installation procedure due to the flexibility of the mini ball screw and the variations of inlet types. The product is amazing it has a rubber gasket attached to it that fits over a 3inch pipe or slides into a 4inch pipe. Oatey surevent abs air admittance valve keeps sewer gases from escaping into any building. Studor mini vent 5 answers i recently had my kitchen remodeled and the plumber installed a studor mini vent under the sink. The mini ball screw can be mounted horizontally or vertically, on a side or end wall or on the ceiling. This minivent advanced air admittance valves aavs protects the trap seals in the drainage system by allowing the intake of air, so that the right level of. Studer onair 1500, digital broadcast mixing console. Can you use air admittance plumbing vent valves on your next. Oct 22, 2008 just moved into my new house and found that i the prep sink in the kitchen constantly has a septic smell coming from it.
It can also be used with other studor aavs to complement larger and highrise building drainage systems and is ideal for all single fixtures. Out l, out r mono the mini vent ii provides a stereo output. I have pulled the toilet four times and run a snake and a garden hose through it. Humbucker guitars and some organs and you notice clipping, the mini vent can be switched to lo gain. Territoires intelligents du groupe caisse des depots. The reducer will change in size from the drain pipes size, either 3 or 4inch, to the studor vent size, either 1 12 or 2inch. One solution is an air admittance valve, or aav, and we. Can be used as an individual, branch, circuit or stack vent. Studor minivent air admittance valve with pvc adapter at menards. The sink does have a studer valve on it but it still lets septic gas into the house. The studor mini vent aav is an accepted alternative to replace all forms of conventional branch and stack venting. Studors minivent dfu drain fixture unit sizing chart from the studor products manual cited and linkedto in this article.
The mini vent for organ is set to lo gain input from the factory. If you cant find the information youre looking for, then please contact us. The unique design of the studor redi vent provides ventilation to prevent the loss of water seals in traps without the need for expensive roof penetration and vent piping. For more than half a century, ips corporation has been continually refiningand redefining plumbing industry technologies. View and download studer onair 2500 operating instructions manual online.
Studor 20341 mini vent with pvc adapter 1 12inch or 2inch connection after suffering from odor in our bathroom for some time i purchased and installed this product. Simplify drainage and waste venting with the studor redi vent. I had a different brand put on last year when there was a lot of pressure it released a gas smell. If an instrument with hotter output signal is connected e. I am pretty sure this either the vent or the break in. Studor 20341 minivent with pvc adapter 1 12inch or 2inch. Studer onair 2500 operating instructions manual pdf download. An air admittance valve shall be acceptable as a vent termination for any individual vent, common vent, circuit vent, loop vent, island fixture vent, vent stack or stack vent that is provided to prevent siphonage of a fixture trap.
Unscrew the 4 screws on the bottom and open the enclosure 3. Product informationspecification sheet studor maxivent. Theres one under the sink in the kitchen, one in the main level laundry room, one under the sink in the master bath, etc. I am planning to relocate my utility room hot water heater, washerdryer and sink to the gargage. Hanspeter liniger, rima mekdaschi studer, christine hauert, mats gurtner. When i stop either drain, fill with water and remove the stopper, the water drains slowly with the studor in place abut will flow freely when it is removed. Buy ezflo 86075 studor mini vent air admittance valve. This document is targeted at key stakeholders in slm. Type l vent installation instructions general information airjet l vent is listed for use with modern highef. Studor maxi vent air admittance valve for plumbing ventilation description the studor maxi vent air admittance valve aav is an accepted alternative to replace all forms of conventional stack venting, utilising active air pressure control, allowing the air to enter the system at the point of need. The unique design of the studor minivent provides plumbing ventilation to prevent the loss of water seals in traps without the need for costly roof penetration and vent piping.
Sewer gas smell coming from studor vent installed under. Can be used with minivent redivent and tecvent only. We were the first to produce a reliable cement for use with pvc, cpvc, and abs pipe and fittings. I plan to install two sinks on opposite walls one for laundry and one for other and instead of running a new vent through the roof i was thinking of using the mini vent instead. This equalizes the pressure within the system and protects the trap seal. Find the jumper soldered flat on the pcb board see picture below 4. Studor mini vent npt 1,5 with global connector dn code 1.
709 894 917 663 1066 1577 510 205 565 391 1330 1242 740 85 618 1296 18 1004 111 698 1467 1189 1642 405 1013 1292 232 1461 297 1161 511 935 753 1484 539